Abstract

Auditory steady-state responses (ASSRs) were elicited by presenting single or multiple, 77-105 Hz amplitude-modulated 0.5, 1, 2, and 4 kHz tones to one or both ears. Objectives of this study were to (i) replicate and extend previous multiple ASSR studies in a quiet double-walled sound booth, and (ii) discover differences (if any) between thresholds assessed in monotic and dichotic conditions, which ranged between 15 and 22dB SPL. The present study's behavioural and ASSR thresholds are 0-10 dB lower (better) than results of previous monotic studies. Further, there are no significant differences in ASSR thresholds between dichotic and monotic stimulus conditions. Therefore, dichotic multiple AM tone stimulation does not produce a change in the ASSR that affects threshold estimation in a clinically significant manner. Thus, at least for detecting normal hearing, the dichotic multiple ASSR technique is a feasible method for estimating hearing thresholds that would substantially reduce recording time compared to conventional single-stimulus techniques.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.