Abstract

Small-signal stability analysis methods based on an impedance criterion originate from the minor loop gain method and are gradually utilized in two-stage DC distributed power systems. In this paper, we conclude that the impedance criterion directly dependent on output impedance Z/sub o/(s) of the source subsystem and input impedance Z/sub i/(s) of the load subsystem is possible but gives an incorrect stability analysis for systems with a regulated source subsystem. Through introducing a mapped pure impedance of the load subsystems and the preliminary system, we develop a general three-step impedance criterion, with which a correct small-signal stability analysis can be guaranteed, regardless of the type of source subsystem. Furthermore, we introduce the application of the three-step impedance criterion in two small-signal stability analysis cases and utilize it in an example system to predict the stability shift process arising from the variation on the load resistance and input voltage value.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.