Abstract
This paper proposes a three-phase power factor correction (PFC) for a three-phase induction motor (IM) drive under normal and abnormal supply voltage conditions. A new technique of PFC based on a positive sequence components method is introduced. The PFC circuit uses a SEPIC converter with a single switch, which needs only one control signal. The PFC control method with the proposed technique provides nearly sinusoidal supply currents maintaining a high power factor under different supply voltage conditions. Furthermore, the PFC method maintains DC bus voltage at the desired value. The regulated DC voltage feeds a four-switch inverter of the three-phase IM drive system. Mathematical analysis of the equivalent circuits based on operation modes of the SEPIC converter is introduced. The performance of the proposed technique is evaluated under ideal and non-ideal supply voltage conditions. The results are analyzed in terms of reduction in the THD of supply currents and improvement of power factor. System validation performed in simulation and experiment has shown the effectiveness of the proposed system under different supply voltage conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.