Abstract

Unintentional lead placement in the left ventricle (LV) is a rare complication of pacemaker implantation. Despite the fact that these procedures are routinely guided by electrocardiography and fluoroscopic imaging, these monitoring methods may occasionally prove to be insufficient. These are the cases when echocardiography, especially three-dimensional (3D) echocardiography, may be of help. An 83-year-old male was admitted to our clinic due to suspected ventricular lead dislocation into the LV, detected in a routine follow-up chest X-ray film. Five years earlier, the patient underwent implantation of a Victory DR (DDDR) cardiac pacing system (from St. Jude Medical) with screw-in leads (atrial Optisense 52 and ventricular Optisense 58) due to complete atrioventricular block. The pacing parameters were good both initially and at the interim follow-up outpatient interrogations. A 12-lead electrocardiogram (ECG) tracing showed normal cardiac pacing in the DDDR mode with pacemaker-generated ventricular complexes of right bundle branch block (RBBB) morphology (Fig. 1A). Lateral-view fluoroscopy revealed the electrode forming a backward-facing arch (Fig. 1C, arrow), which is consistent with the ventricular lead passing from the right atrium (RA) through the foramen ovale into the LV. A detailed, three-dimensional (3D) course of both leads was visualised via 3D echocardiography. During lead insertion the ventricular lead was deflected by an abnormally large muscle rim in the RA, which altered its course (Fig. 2A). The lead passed from the RA through the anterior edge of the foramen ovale, and into the left atrium (LA) (Fig. 2B). Finally, the lead passed through the mitral valve at the border of segments P2 and P3 into the LV (Fig. 3A), where its tip eventually rested in the basal part of the lateral apical segment of the LV (Fig. 3B). Right endocavitary pacing produces electrocardiographic evidence of left bundle branch block (LBBB). However, RBBB can also be seen in 8.3% of ECG tracings, a proportion that can be reduced to 4.3% by tracing modification with the Klein’s manoeuvre (lowering precordial leads by one intercostal space). Radiographic anterior-posterior images do not always show lead placement accurately and may fail to visualise complications of permanent pacing. In the case presented here, the suspected complication was confirmed echocardiographically. The 3D mode allowed an accurate visualisation of lead placement in the LV and helped explain the likely cause of lead misdirection. Figure 2. A, B. Three-dimensional transoesophageal echocardiography — two views from the middle oesophagus, modified. The lead passes through interatrial septum (IAS) in the anterior part of the foramen ovale; LA — left atrium; LV — left ventricle; RA — right atrium; TV — tricuspid valve

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.