Abstract

Symmetrization of the radiation field inside hohlraum targets for indirectly driven heavy ion beam inertial confinement fusion (ICF) is investigated numerically. The targets considered consist of a casing, enclosing the spherical fuel capsule, and a few cylindrical radiators, schematically representing ion beam irradiated converters. Radiation absorption and re-emission are dealt with as in the paper by Murakami and Meyer-ter-Vehn (Nucl. Fusion 31 (1991) 1333), but with the geometry extended to three dimensions and with the finite size of the radiators taken into account. It is found that, for a practical casing to capsule area ratio (of the order of ten) and practical converter aspect ratios, two converters (allowing for two-side axisymmetric irradiation) cannot provide the uniformity required for ICF. However, with a spherical casing with six converters (placed in couples along the axes of a Cartesian co-ordinate system) it would be possible to illuminate a capsule with a non-uniformity well below 2%, which could satisfy the ICF requirements. The effects of changing the area ratio, the size and position of the converters and the geometry of the hohlraum are also discussed

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.