Abstract
Four-leg inverters have been selected as one of the preferred power converter topologies for applications that require a precise control of neutral current, like active filters. The main advantage of this topology lies in an extended range for the zero sequence voltages and currents. However, the addition of a fourth leg extends the space vectors from two to three dimensions, making the selection of the modulation vectors more complex. Most of the algorithms that deal with this problem require an /spl alpha//spl beta//spl gamma/ transformation. This paper presents a new space vector modulation algorithm using abc coordinates (the phase voltages) avoiding the /spl alpha//spl beta//spl gamma/ transformation. Thanks to the use of abc coordinates, the algorithm is much simpler and more intuitive than in /spl alpha//spl beta//spl gamma/ representation, drastically reducing the complexity of modulation algorithm and the computational load associated to it.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.