Abstract

In three-phase four-wire systems and unbalanced mode, the four-leg inverters have been considered as one of the adapted topologies of the power converters for the application which require a very strict and precise control of the neutral current, caused by the unbalanced and/or nonlinear load or unbalanced source. In this paper, we present a theoretical study of the control technique for this inverter used as an active filter; this method is called a three dimensional space vector modulation (3DSVM). Simulation results are presented and discussed to verify the performance of this control method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.