Abstract
Non-destructive testing (NDT) of materials and structures is a very important industrial issue in the fields of transport, aeronautics and space as well as in the medical domain. Active infrared thermography is an NDT method that consists of providing an external excitation to cause an elevation of the temperature field in the material, consequently allowing evaluation of the resulting temperature field at the surface. However, thermal exciters that are used (flash lamps, halogen, lasers) act only on the surface of the sample. On the other hand, several energy conversion systems can lead to the generation of volumetric sources; the phenomena of thermo-acoustics, thermo-induction, thermomechanics or thermochemistry can be cited. For instance, ultrasonic waves can generate volumetric heat sources if the material is viscoelastic or if there is a defect. The reconstruction of these sources is the initial process for the quantification of parameters responsible for the heating. Characterizing a heat source means reconstructing its geometry and the supplied power. Identification of volumetric heat sources from surface temperature fields is a mathematically ill-posed problem. The main cause of the issue is the diffusive nature of the temperature. In this work, 3D reconstruction of the volumetric heat sources from the resulting surface temperature field, measured by infrared thermography, is studied. An analysis of the physical problem enables specifying the limits of the reconstruction. In particular, a criterion on the achievable spatial resolution is defined, and a reconstruction limitation for in-depth sources is highlighted.
Highlights
Active infrared thermography is a widely used method in non-destructive testing (NDT).The process involves exciting the environment studied with the help of an external energy supply, and measuring the resulting temperature on the surface
One of the disadvantages of thermal NDT is that the excitation and the measurement are on the surface
Exciters today used in thermal NDT are usually flash lamps, halogens or lasers, which act only on the surface of the material, making access to information in the volume difficult
Summary
Active infrared thermography is a widely used method in non-destructive testing (NDT). The process involves exciting the environment studied with the help of an external energy supply, and measuring the resulting temperature on the surface. One of the disadvantages of thermal NDT is that the excitation and the measurement are on the surface. Exciters today used in thermal NDT are usually flash lamps, halogens or lasers, which act only on the surface of the material, making access to information in the volume difficult. Several energy conversion systems can, lead to the appearance of volumetric sources in a material: phenomena of thermo-acoustics, thermo-induction, thermomechanics or thermochemistry can be cited. An excitation by ultrasonic waves can lead to heat sources in a material if it is viscoelastic or if it contains a defect.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.