Abstract

Lateral interbody fusion provides a significant biomechanical advantage over the traditional transforaminal lumbar interbody fusion due to the large implant size and optimal implant position. However, current methods for lateral interbody cage placement require either a two-staged procedure or a single lateral decubitus position that precludes surgeons from having either full access to the posterior spine for direct decompression or comfortable pedicle screw placement. Herein is one institution's experience with 10 cases of a prone single-position approach for simultaneous access to the anterior and posterior lumbar spine. This allows both lateral lumbar interbody cage placement, direct posterior decompression, and pedicle screw placement, all in one position. Three-dimensional (3D) navigation is utilized for increased precision in both approaching the lateral spine and interbody cage placement. The traditional blind psoas muscle tubular dilation was also modified. Tubular retractors and lateral vertebral body retractor pins were used to minimize the risks to the lumbar plexus.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.