Abstract

To quantify the procedure-related complication rate after using modified technique of amniocentesis with a 29-gauge (29-G) pencil-point needle. This is a prospective, descriptive study of 316 amniocenteses that were performed by means of atraumatic 29-G pencil-point needle under ultrasound control. A total of 316 amniocenteses were observed through the postprocedural period. The median time needed to retrieve 15 mL of amniotic fluid was 4 min. A total of 19 pregnancies were terminated after genetic testing. No case was regarded as procedure-related fetal loss. No other complications were observed. Seventeen children were born before 37 completed weeks of gestation and five children had a birth weight <2000 g. Amniocentesis with the 29-G atraumatic pencil-point needle seems to be a safe procedure with extremely low risk of complications and is a good alternative to the traditional 22-G Quincke needle.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.