Abstract
AbstractSince three‐phase transformerless (TPT) PV inverters have large common mode leakage current (CMLC), a TPT PV inverter without CMLC is proposed. The proposed inverter is derived from three single‐phase half‐bridge inverters and a boost converter. Grounds of the PV array and three‐phase loads are connected directly, so no CMLC exists in the TPT solar inverter. Operating principle, stability analysis, and loss calculation and example of the proposed three‐phase inverter are illustrated in detail. The pulse‐width modulation (PWM) and sinusoidal PWM control methods are used in the boost converter and three‐phase inverter, respectively. The proposed inverter is a stable system. Finally, simulation and experimental results of a 900‐W TPT PV inverter confirm the theoretical analysis. The CMLC in the proposed inverter is only about 0.8 mA, which is mainly caused by the ground line inductance and oscilloscope probe noise.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.