Abstract

The five-leg back-to-back converter shares a leg between the grid and load sides. In the conventional five-leg converter, all legs are of same type, i.e., either two- or three-level legs. This paper presents topologies of five-leg converters based on the combination of two- and three-level legs. The proposed configurations permit one to obtain intermediary characteristics between the five-leg converter with all three-level legs and that with all two-level legs. The choice of the number of two- and three-level legs and how combine them are shown in order to obtain some characteristics of the grid- and load-side converter voltages. The modeling of the system and the pulsewidth-modulation strategy based on carrier-based and space-vector approaches is presented. Analysis of the total harmonic distortion and power switches losses are also addressed to characterize the configurations. Experimental and simulated results show the system feasibility.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.