Abstract

A combination of phase-shift with gray-code light projection into a three-dimensional vision system based on the projection of structured light is presented. The gray-code method is exploited to detect without ambiguity even marked surface discontinuities, whereas the phase-shift technique allows the measurement of fine surface details. The system shows excellent linearity. An overall mean value of the measurement error equal to 40 microm, with a variability of approximately +/-35 microm, corresponding to 0.06% of full scale, has been estimated. The implementation of the technique is discussed, the analysis of the systematic errors is presented in detail, and the calibration procedure designed to determine the optimal setting of the measurement parameters is illustrated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.