Abstract

Terahertz coded-aperture imaging (TCAI) can overcome the difficulties of traditional radar in forward-looking and high-resolution imaging. Three-dimensional (3D) TCAI relies mainly on the reference-signal matrix (RSM), the large size and poor accuracy of which reduce the computational efficiency and imaging ability, respectively. According to the previous research on TCAI, traditional TCAI cannot reduce the heavy computational burden while the improved TCAI achieve reconstructing the target parts of different ranges in parallel. However, large-sized RSM still accounts for the computational complexity of traditional TCAI and the improved TCAI. Therefore, this paper proposes a more efficient imaging method named back projection (BP)-TCAI (BP-TCAI). Referring to the basic principle of BP, BP-TCAI can not only divide the scattering information in different ranges but also project the range profiles into different imaging subareas. In this way, the target parts in different subareas can be reconstructed simultaneously to synthesize the whole 3D target and thus decomposes the computational complexity thoroughly. During the pulse compression and projection processes, the signal-to-noise ratio (SNR) of BP-TCAI is also improved. This present the imaging method, model and procedures of traditional TCAI, the improved TCAI and the proposed BP-TCAI. Numerical experimental results prove BP-TCAI to be more effective and efficient than previous imaging methods of TCAI. Besides, BP-TCAI can also be seen as synthetic aperture radar (SAR) imaging with coding technology. Therefore, BP-TCAI opens a future gate combining traditional SAR and coded-aperture imaging.

Highlights

  • Traditional radar imaging method relies too much on the relative motion between the radar and target to achieve forward looking and staring imaging

  • According to the extracted echo vector (EV) and Equations (16)–(20), the corresponding reference-signal matrix (RSM) are built for high‐resolution imaging of back projection (BP)‐terahertz coded-aperture imaging (TCAI)

  • According to the extracted EVs and Equations (16)–(20), the corresponding RSMs are built for high-resolution imaging of BP-TCAI

Read more

Summary

Introduction

Traditional radar imaging method relies too much on the relative motion between the radar and target to achieve forward looking and staring imaging. Terahertz coded-aperture imaging (TCAI) [1,2,3] can overcome the difficulties with a high resolution. Based on the imaging principles of both optical coded-aperture imaging [4,5] and radar coincidence imaging (RCI) [6,7], TCAI achieves reconstructing the target by producing spatiotemporal independent signals with the coded aperture. Terahertz waves (0.1–10 THz) allow visualization of hidden object at millimeter level [8,9,10]. Because of the promising ability in flexible manipulation on terahertz and millimeter waves, metasurfaces have been applied into areas of high-resolution computational imaging [11,12] and some scanning devices [13,14].

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call