Abstract

Using a hybrid approach, 3-D simulations of magnetic priming of a relativistic magnetron have been performed. The primed magnetic field values were calculated using a magnetostatics code (Magnum) and then imported into a particle-in-cell code (Magic PIC) and run for the case of a six-vane relativistic magnetron. The magnetically perturbative structures chosen for implementation in these simulations were sets of three high-permeability wires of various lengths, which would be placed within the cathode, the anode, or, in the combined case, both the cathode and anode. In the best-performing cathode-wire case (three 4-cm wires), magnetic priming was found to reduce the start-oscillation time of the magnetron to 50% that of the unprimed case. When wires were embedded in both the cathode and the anode, the best-performing case (4-cm cathode wires and 4-cm anode wires) was found to start oscillating at 30% of the start-oscillation time of the unprimed case. The cases of magnetically primed magnetrons were found to exhibit slightly reduced equilibrium power levels, compared with the unprimed case.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.