Abstract

This paper presents a novel low cost three dimensional near-field scanning system consisting of a near field scanner and a three dimensional magnetic probe which reduces the large scanning time of the existing near field scanning systems and increases the spatial resolution. The paper focuses on the design, calibration and validation of a printed circuit three dimensional magnetic field probe. The proposed probe is printed on both sides an FR4 substrate of 3.2mm height. The total dimensions of the probe are 9×9×3.2mm3. The antenna factor of the designed probes is calculated using TEM cell for a frequency range from 10 MHz to 1 GHz. The proposed scanning system is validated by mapping the magnetic field above a wire over ground structure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.