Abstract
3-D neutronics and shielding analyses have been performed for the divertor region of the ITER interim design. The peak neutron wall loading in the divertor region is 0.6 MW/m{sup 2} at the divertor cassette dome. The total nuclear heating in the 60 divertor cassettes is 102.4 MW. The peak helium production in the VV behind the pumping ducts is 0.5 He appm/FPY implying that rewelding might be feasible. The total nuclear heating in the parts of the TF coils in the divertor region is only 2.1 kW. 5 refs., 4 figs., 5 tabs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.