Abstract
Complexities of the underwater environment can seriously affect many underwater detection means, especially the influence of light scattering by water. To solve this problem, a three-dimensional (3D) morphology measurement method is proposed based on the photoacoustic effect. In this method, a measurement object is irradiated with pulsed laser light to produce ultrasonic waves via the photoacoustic effect. A probe collects the ultrasonic signal and subsequent data processing can yield complete object detection. This approach can make full use of the advantages of high precision and good directivity of laser ranging and completely avoid the influence on the laser of backscattering from water. The results yield a displacement measurement accuracy of less than 0.5 mm and an average error of 3D reconstruction of 0.21 mm, demonstrating great application potential.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.