Abstract
In fusion reactor blanket design, liquid metals are attractive working fluids since it is possible to combine in a single fluid the functions of coolant, tritium carrier and breeder. These electrically conductive fluids flow in the presence of a strong magnetic field, inducing the appearance of Lorentz forces and magnetohydrodynamic MHD effects. Increased pressure loss, particularly in complex geometry elements, is a critical point for blanket design. The MHD flow through an orifice plate made by electroconductive walls (c = 0.01 ÷ 0.1) has been analysed in this paper using ANSYS CFX in the range Re = 108, and Ha = 0 ÷ 300. A wide recirculation region is detected after the flow exits the orifice, with potentially harmful consequences for efficient tritium removal. Large pressure loss occurs in the orifice due to conductive wall and non-negligible axial length. The 3D pressure drop term is characterized through a local resistance coefficient (k) that is found to be k ≈ 0.205 for well conducting walls (c = 0.1) and k ≈ 0.063 for poorly conducting ones (c = 0.01).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.