Abstract
The cause of high operating temperatures experienced by grate blocks in a waste-to-energy power plant is investigated. A three-dimensional numerical analysis is performed to assess convection from the grate to the underfire air supply and conduction within the grate. A number of geometric complexities, including variable solid thickness, extended surfaces, sharp curvatures, and narrow passages, are accounted for via a finite element approach. The grate temperature is found to be very sensitive to the flow characteristics beneath the grates. Analysis of a modified grate structure was performed, showing a 14% reduction in maximum grate temperature.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.