Abstract

OBJECTIVE: This 3-D FEA study compared the stress distribution in two-implant mandibular overdentures as a function of implant position and attachment system (LA: locator attachment vs. BA: ball attachment).METHODS: Four models of mandibular overdentures were tested: M1-LA – with implants at the canine regions (standard implant position) and LA; M2-LA – with implants placed at the first premolar regions (distalized implant position) and LA; M1-BA – with standard implant position and BA; and M2-BA – with distalized implant position and BA. The geometric models were converted into finite element models. A 100 N axial load was applied at the first molar region. The von-Mises stress distribution was compared in selected points.RESULTS: The models with BA had pattern of stress distribution was more uniform along the implant axis than the ones with LA, although the stress magnitude was larger. The largest area of von Mises stresses on the alveolar ridge was in the models with standard implant distribution.CONCLUSION: The findings showed that the models with BA had better biomechanical behavior than the ones with LA. For both types of attachment, the models with increased inter-implant distance presented a smaller area of stress distribution in the perimplant cortical bone tissue than the standard implant position.

Highlights

  • Two-implant overdentures are considered the first choice for treatment of edentulous mandibles due to more efficient retention, stability, masticatory performance, and patients' satisfaction and quality of life in comparison with conventional complete dentures [1, 2]

  • For the locator attachment models, the area of stress distribution were similar for M1 and M2, with the largest areas of stress observed in the middle and cervical thirds of the implant, male locator attachment, and female locator attachment

  • For the ball attachments and implant, the area of stress distribution were similar for M1 and M2, with the largest areas of stress observed in the body of the ball attachment and in the implant platform (Figure 4)

Read more

Summary

Introduction

Two-implant overdentures are considered the first choice for treatment of edentulous mandibles due to more efficient retention, stability, masticatory performance, and patients' satisfaction and quality of life in comparison with conventional complete dentures [1, 2]. The stability and retention of overdentures are promoted by the implant-attachment-prosthesis connection systems. The biomechanical behavior of these systems was studied mainly by means of the prosthesis retention [5,6,7,8,9,10,11,12] or the bone-implant-abutmentattachment-prosthesis interaction [6, 13,14,15,16]. There are still limited studies that have addressed the optimization of this type of treatment with alternative implant localization designs across attachment systems [3, 4]

Methods
Results
Conclusion
Full Text
Published version (Free)