Abstract

The detailed analyses were conducted on three-dimensional fiber orientation of thin FRTP plate with a pinpoint-gate at the center. To visualize the 3 D fiber orientation, X-ray transmission CT was used and the following conclusions were obtained.1) Owing to the change in flow direction from expanding flow in the filling stage to shear flow in the packing stage, the fiber orientation at the exit of the gate changes from concentric alignment to radial one.2) Molding conditions such as injection speed, mold temperature and resin temperature have slight influence on the fiber orientation.3) The development of shear flow is easily affected by plate thickness and gate dimension. Thinner plate thickness and smaller gate size bring about lower fiber orientation because of less shear flow development.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.