Abstract
A 28-year-old woman was referred to closure of a residual shunt produced through a percutaneous device previously implanted in the atrial septum. The imaging protocol to guide the procedure included 2D TEE and real time 3D (RT3D) transesophageal echocardiography (TEE) imaging. RT3D TEE facilitated the evaluation of the defect morphology, and the relationship with the previous device, allowing a proper understanding of the mechanism responsible for the residual shunt. It was also a useful tool for guiding device deployment, providing clear intraprocedural information about catheter position and the spatial relationship with the previous device. In conclusion, RT3D TEE and 2D TEE are complementary techniques for the evaluation and guidance of transcatheter closure of complex atrial septal defects.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.