Abstract

A new x-ray tomographic method to image a particular element is proposed and described. This method uses an x-ray tube spectrum and a pair of balanced filters with absorption edges just above and just below the edge of the desired element. The proposed system consists of a microfocus x-ray tube as an x-ray source and a 2-D detector array to collect projection data. The main advantage of this system over traditional differential tomography using two monoenergetic sources is its easy application to fan-beam or cone-beam geometry without reducing too much its intensity. ART is used to reconstruct the 3-D images from the simulated projection data generated by a Monte Carlo program. Computer experiments demonstrate the feasibility of selective imaging in cone-beam geometry.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.