Abstract
The administration of a contrast agent to obtain optimal images at three-dimensional computed tomographic (CT) angiography of the hepatic artery by using multi-detector row helical CT was investigated. Three-dimensional CT angiographic images were evaluated visually, and quantitative evaluation was performed by measuring the postcontrast CT number of the aorta. The injection rate of 5 mL/sec was significantly superior to that of 4 mL/sec in both evaluations. At administration of a contrast agent with 300 or 350 milligrams of iodine per milliliter, there were no significant differences in either evaluations. The preferable injection rate to obtain sufficient three-dimensional CT angiographic data was 5 mL/sec.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.