Abstract

Three-dimensional flue gas flow fields and temperature profiles are calculated in a 4/2/1 split coil naphtha-cracking furnace with long flame burners and an asymmetric flue gas outlet. The heat streams in the furnace connected to the asymmetric flue gas flow fields are found to be compensated for by a net radiative heat transfer in the opposite direction. As a result, the temperature distribution in the furnace remains nearly symmetrical. A furnace simulation under conditions of nonuniform heating confirms the compensating nature of radiative heat streams in the furnace. Furthermore, nonuniform heating was found to improve the thermal efficiency of the furnace and the cracking results. Optimization of heating conditions remains a point of interest.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.