Abstract

The contourmeter was used to determine quantitatively the denture displacements caused by various impression materials and techniques during the relining of a maxillary denture. This study indicated the following conclusions. Tissue-conditioning material used with closed-mouth impression technique or light-bodied polysulfide used with either open- or closed-mouth technique caused the least denture displacement in the three dimensions when compared with regular-bodied polysulfide or zinc oxide and eugenol impression materials. Comparing the same impression materials used with either open- or closed-mouth technique showed no significant difference in maxillary denture displacements. A relined complete denture should be remounted on the articulator and the occlusion refined to eliminate occlusal mismatches resulting from three-dimensional denture displacements during relining.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.