Abstract
Abstract We summarized the experience from three decades of oxygen transfer testing and aeration research at the Technical University of Darmstadt to validate the oxygen transfer efficiency of modern fine-bubble diffusers. A total of 306 oxygen transfer tests in clean water of 65 different fine-bubble diffusers, carried out in the same test tank under identical test conditions, were analysed and compared with previous results. As a result, we could show that the performance of fine-bubble aeration systems has increased by 17% over the last three decades. Therefore, modern well-designed and operated aeration systems can achieve specific standard oxygen transfer efficiency (SSOTE) values between 8.5 and 9.8% · m−1. Additionally, a comparison of various diffuser types and diffuser densities was done. Based on the new results, an exemplary cost/benefit analysis for a 100,000 PE WWTP shows the calculation of an optimized diffuser density with respect to investment and operating costs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.