Abstract

Introduction. Firefighters are taught that heat, oxygen deprivation, andcarbon monoxide (CO) are the primary threats to life in residential structure fires, andthey are taught to search for victims on the fire floor first, andthen floors above. The objective of this study was to gather data regarding oxygen, CO, andheat conditions inside a realistic house fire, to examine the validity of these teachings. Methods. During six live-burn training evolutions in a two-story wood-frame house, metering for oxygen levels, CO levels, andtemperature was conducted. Except where noted, all readings were taken 24 inches off the floor, to simulate the location of a crawling victim or firefighter. Readings were hand-recorded on a convenience basis by firefighters stationed outside the building, near the meters. Results. Of the 35 oxygen levels recorded, the lowest was 18.2%, with only 12 readings below 20%. Three of 16 first-floor readings were below 20%, whereas nine of 19 second-floor readings were below 20% (p = 0.07). First- andsecond-floor readings were comparable (mean 20.3% vs. 19.9%, p = 0.11). Except for one reading of 1,870 ppm, all CO readings at the ceiling exceeded the 2,000-ppm limit of the meters. Of the 34 CO levels recorded 24 inches off the floor, 29 (76%) exceeded the permissible exposure limit of 50 ppm, with the highest reading being 1,424 ppm, well above the “immediately dangerous to life andhealth” level of 1,200 ppm. None of the 20 CO levels recorded on the first floor exceeded the 30-minute exposure limit of 800 ppm, whereas seven of 14 second-floor readings exceeded this limit (p < 0.001). While ceiling temperatures frequently exceeded the 1,000°F limit of the meters, none of 16 readings taken 24 inches off the floor exceeded 137°F. First- andsecond-floor temperatures were comparable (mean 88.5°F vs. 90.1°F, p = 0.9). Conclusions. In residential structure fires, CO poses a greater threat to victims andfirefighters than does oxygen deprivation or heat. Emergency medical services personnel should consider CO toxicity in all fire victims. Conditions on the floor above a fire are at least as adverse as those on the fire floor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.