Abstract

The purpose of the study was to implement a three-dimensional (3D) magnetic resonance (MR) angiographic technique with acquisition times on the order of 800 msec with use of a spoiled gradient-echo pulse sequence (repetition time, 1.60 msec; echo time, 0.65 msec) and bolus intravenous injection of contrast material doses as small as 6 mL. High-spatial-resolution conventional MR angiography performed with 30 mL of gadopentetate dimeglumine was the reference standard. As implemented, subsecond 3D MR angiography allowed temporal sampling that was rapid enough to depict short-lived processes, as illustrated in patients with shunts and dissections. With small contrast material doses and subsecond frame rates, it is also possible to measure pulmonary arteriovenous circulation times with this 3D MR angiographic technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.