Abstract

Methods Thoratec Centrimag ® was used in 22 cardiogenic shock patients. All were INTERMACS class I and all but one had multiorgan failure. Seventeen (77%) were male, mean age 41+13 years. Etiology was ischemic in 11(50%), dilated in 4(22%), and other etiology in 7(32%). Nine (41%) had previous cardiac arrest with a mean arrest time of 18+16 min. Circulatory support was biventricular in 18(82%), univentricular 4(18%), and in 6(27%) an oxygenator was interposed within the outflow line until respiratory recovery. Patients with veno-arterial ECMO configurations were excluded. Results Bridge-to-transplant or recovery was obtained in 14 out of 22 (64%). Mean support time 44 days, range 1-292 days. Eight patients (36%) were supported for more than 4 weeks. Thirty-day post-implant survival was 73% (16 patients). Post-implant complications were re-exploration for bleeding 7(32%), neurologic dysfunction 3(14%), pneumonia 8(36%), and renal failure with dialysis in (32%). Eleven (50%) patients are in NYHA class I after a mean follow-up time of 32+6 months. Kaplan Meier one-year survival was 56+11%. Eleven out of 12 (92%) bridged-totransplant are in NYHA functional class I with normal biventricular function. One patient died 3 days posttransplant due to inflammatory response. Two patients were bridged-to-recovery. One is in NYHA class I and the other died due to non-compliance. Conclusion Thoratec Centrimag ® is useful to provide intermediateterm circulatory support for cardiogenic shock and multiorgan failure in a developing country. Support time longer than 4 weeks is feasible. A multidisciplinary approach is needed since morbidity is common.

Highlights

  • Circulatory support is usually not available in developing countries due to cost restrictions

  • We report our experience in the treatment of cardiogenic shock with this intermediate-term device

  • Thoratec Centrimag® was used in 22 cardiogenic shock patients

Read more

Summary

Background

Circulatory support is usually not available in developing countries due to cost restrictions. We report our experience in the treatment of cardiogenic shock with this intermediate-term device

Methods
Conclusion
Results
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.