Abstract

ObjectiveTo evaluate the efficacy and safety of a modified technique for totally thoracoscopic left atrial posterior wall and pulmonary vein isolation in patients with long-standing persistent atrial fibrillation.MethodsFrom April 2017 to December 2018, we included in this study 28 consecutive patients who underwent thoracoscopic left atrial posterior wall and pulmonary vein radiofrequency isolation combined with left atrial appendage resection. We used a device with irrigated electrodes (Medtronic Cardioblate Gemini-s). The original surgical technique “GALAXY” proposed by Doty in 2012 was modified. The number of ablations was significantly increased, and frequent position changing of the ablation device and change of device angulation were added.ResultsSinus rhythm was restored in all patients. There was no operative mortality, no myocardial infarction, and no stroke or transient ischemic attack. One patient required sternotomy and another survived left anterolateral thoracotomy due to bleeding. A 180-day follow-up (24-hour Holter monitoring) revealed no sign of recurrence of atrial fibrillation or other supraventricular arrhythmia in any patient. Mean follow-up was nine months (range: 6-16 months). At the last follow-up, 26 patients (92,9%) were in sinus rhythm (24-hour Holter monitoring).ConclusionA frequent ablation device position changing during the surgery makes it possible to achieve complete left atrial posterior wall and pulmonary veins isolation. An increased number of applications allows to avoid a false positive transmural damage assessment showed by impedance drop. Also, frequent position changing of the ablation device and increased number of applications do not affect the number of postoperative complications.

Highlights

  • Atrial fibrillation (AF) has a rising prevalence in the general population, and this condition is associated with reduced longterm survival and impaired quality of life[1]

  • The number of ablations was significantly increased, and frequent position changing of the ablation device and change of device angulation were added

  • A frequent ablation device position changing during the surgery makes it possible to achieve complete left atrial posterior wall and pulmonary veins isolation

Read more

Summary

Introduction

Atrial fibrillation (AF) has a rising prevalence in the general population, and this condition is associated with reduced longterm survival and impaired quality of life[1]. The low quality of life is caused by need for constant anticoagulation, antiarrhythmic, and other negative chronotropic drugs. These can cause significant reduction in functional capacity and development of significant complications with time[2,3,4,5]. This study was carried out at the Federal Research and Clinical Centre, Moscow, Russian Federation.

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.