Abstract

Three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiography is a promising technique for thoracic aortography that complements electrocardiographically gated T1-weighted spin-echo imaging and cine MR imaging. Axial and left anterior oblique T1-weighted spin-echo images are well suited to measurement of aortic dimensions and evaluation of aortic aneurysms. Sagittal and coronal spin-echo images are helpful in evaluation of vascular rings and aortic dissection. Cine gradient-echo and cine phase-contrast imaging allow dynamic evaluation of aortic and valvular flow. Cine phase-contrast imaging also enables noninvasive quantification of blood flow. Capable of being performed during a single breath hold, 3D gadolinium-enhanced MR angiography provides high-resolution 3D data that can be readily used for projection angiography and multiplanar reformation. This technique enables further demonstration of subtle pathologic conditions. Three-dimensional gadolinium-enhanced MR angiography allows more comprehensive and efficient evaluation of the thoracic aorta.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.