BackgroundWeaning of patients from the mechanical ventilation remains one of the critical decisions in intensive care unit. This study aimed to evaluate the accuracy of thoracic fluid content (TFC) as a predictor of weaning outcome.MethodsAn observational cohort study included 64 critically ill surgical patients who were eligible for extubation. Before initiating the spontaneous breathing trial, the TFC was measured using the electrical cardiometry technology. Patients were followed up after extubation and divided into successful weaning group and failed weaning group. Both groups were compared according to respiratory and cardiovascular parameters. Receiver operating characteristic (ROC) curves were constructed to evaluate the ability of TFC to predict weaning outcome.ResultsThe number of successfully weaned patients was 41/64 (64%). Twenty (31%) patients had impaired cardiac contractility, and of them, 13/20 (64%) patients were successfully extubated. Both groups, successful weaning group and failed weaning group, were comparable in most of baseline characteristics; however, the TFC was significantly higher in the failed weaning group compared to the successful weaning group. The area under the ROC curves (AUCs) showed moderate predictive ability for the TFC in predicting weaning failure (AUC [95% confidence interval] 0.69 [0.57–0.8], cutoff value > 50 kΩ−1), while the predictive ability of TFC was excellent in the subgroup of patients with ejection fraction < 40% (AUC [95% confidence interval 0.93 [0.72–1], cutoff value > 50 kΩ−1).ConclusionsThoracic fluid content showed moderate ability for predicting weaning outcome in surgical critically ill patients. However, in the subgroup of patients with ejection fraction less than 40%, TFC above 50 kΩ−1 has an excellent ability to predict weaning failure.

Highlights

  • Weaning of patients from the mechanical ventilation remains one of the critical decisions in intensive care unit

  • The electrical cardiometry-derived thoracic fluid content (TFC) is measured through the impedance cardiography technology; TFC is assessed through the changes in the impedance of thoracic tissue to the electric current [9]

  • We aimed to evaluate the accuracy of TFC, as an estimate of lung congestion, in predicting weaning outcome in critically ill patients

Read more

Summary

Introduction

Weaning of patients from the mechanical ventilation remains one of the critical decisions in intensive care unit. Various measures had been previously reported for evaluation of volume status before the SBT aiming to identify patients who would benefit from diuretic therapy [5]. Thoracic fluid content represents the whole (extravascular, intravascular, and intrapleural) fluid component in the thorax; TFC was postulated to provide an estimation of the extravascular lung water. We aimed to evaluate the accuracy of TFC, as an estimate of lung congestion, in predicting weaning outcome in critically ill patients. This study aimed to evaluate the accuracy of thoracic fluid content (TFC) as a predictor of weaning outcome

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.