Abstract
ObjectiveWe evaluated images of patients undergoing a thoracic endovascular aortic repair procedure using two reference points as a means for differentiating stent graft migration from aortic elongation. Conventional standards define migration of a stent graft as an absolute change in the distance from the distal graft ring to a distal landmark ≥10 mm compared with a baseline measurement. Aortic elongation occurs over time in both healthy individuals and patients with aortic disease. Aortic elongation in patients with stent grafts may result in increased distal thoracic aortic lengths over time. False-positive stent graft migration would be defined when these patients meet the standard definition for migration, even if the stent has not moved in relation to the elongating aorta. MethodsThis retrospective study evaluated the aortic length of 23 patients treated with the conformable GORE TAG thoracic endoprosthesis (W. L. Gore & Associates, Flagstaff, Ariz) in three clinical trials (dissection, traumatic injury, and aneurysm). Patients who met the standard definition for migration were selected. A standardized protocol was used to measure aortic centerline lengths, including the innominate artery (IA) to the most distal device ring, the IA to the celiac artery (CA), and the distal ring to the CA. Baseline lengths obtained from the first postoperative image were compared with length measurements obtained from the first interval at which they met the standard definition for migration. The conventional standards for migration using a single reference point were compared with the use of dual reference points. ResultsOf the 23 patients with endograft changes, 20 were deemed to have aortic elongation rather than true migration. The remaining three patients were deemed to have migration on the basis of the IA to distal ring position compared with the IA to CA length change. The IA to CA interval length change was markedly greater in those with elongation compared with migration (23.8 ± 8.4 mm vs −3.5 ± 5.4 mm, respectively; P < .05). The distal ring to CA interval length change was greater in patients showing elongation rather than migration (18.5 ± 6.6 mm vs −9.8 ± 5.4 mm, respectively; P < .05). The distance between the IA and distal ring was similar for elongation and migration. ConclusionsThese results highlight the dynamic changes that can occur in the aorta as a natural consequence of age. Employing two landmarks can account for these changes and proves to be an important factor, among others, in the differentiation of aortic elongation from true stent graft migration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.