Abstract

AbstractFluorescent molecular rotors can be used as molecular sensors for the viscosity of a microenvironment. However, these molecular rotors are limited to 9‐(dicyanovinyl)julolidine (DCVJ) and a few derivatives. Furthermore, these traditional rotors show short absorption/emission wavelengths and small Stokes shifts. To address these drawbacks, we have developed a small library of new molecular rotors for viscosity sensing, prepared by incorporating a thiophene unit into the conventional fluorescent molecular rotors with the aim of accessing molecular rotors with redshifted excitation/emission wavelengths and larger Stokes shifts compared with the known rotors. The new rotors show substantially improved photophysical properties. For example, rotor 4 shows absorption/emission wavelengths of 559/697 nm, respectively, and a very large Stokes shift of 138 nm compared with the absorption/emission wavelengths (465/503 nm) and very small Stokes shift (38 nm) of the traditional fluorescent molecular rotor DCVJ. The photophysical properties of the rotors were rationalized by DFT calculations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.