Abstract

Different polyaniline (PANI) based lightning strike protection (LSP) coating thicknesses were tested against simulated lightning strike tests to evaluate the threshold thickness of the coating. A series of lightning strike tests were performed on carbon/glass fiber reinforced polymer (CFRP/GFRP) composites subjected to simulated lightning currents ranging from 40 to 100kA. Five LSP-coated specimens were considered herein: two CFRP and three GFRP composites. A minimum of ∼ 345 μm thick PANI-based LSP coating on CFRP and GFRP composites under a 40 kA peak current retained 83 % and 100 % residual strength, respectively. Additionally, GFRP specimens tested against 60 and 100 kA peak currents exhibited 100 % residual strength. This study proposes that a PANI-based LSP coating is suitable for protecting GFRP composites, while the careful design is necessary for CFRP composites to avoid any catastrophic failure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.