Abstract

Swept-frequency eddy current measurement of pipe thickness is studied in this paper. First, suitable frequency range of swept-frequency eddy current testing is determined by comparing sensitivities of relative reactance change with respect to pipe thickness and other parameters at different frequencies. Based on analytical solutions to pipe eddy current field, Levenberg–Marquardt algorithm and variable transformation, a method for solving inverse eddy current problem is developed. Finally, several inversion calculations are carried out and the results are close to the truth values. The low errors reveal that the method presented in this paper is appropriate.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.