Abstract

Martensitic 9% Cr steels like P91 and P92 show susceptibility to delayed hydrogen assisted cracking depending on their microstructure. In that connection, effective hydrogen diffusion coefficients are used to assess the possible time-delay. Limited data on room temperature diffusion coefficients reported in literature vary widely by several orders of magnitude (mostly attributed to variation in microstructure). Especially P91 weld metal diffusion coefficients are rare so far. For that reason, electrochemical permeation experiments had been conducted using P92 base metal and P91 weld metal (in as-welded and heat-treated condition) with different thicknesses. From the results obtained, diffusion coefficients were calculated using to different methods, time-lag, and inflection point. Results show that, despite microstructural effects, the sample thickness must be considered as it influences the calculated diffusion coefficients. Finally, the comparison of calculated and measured hydrogen concentrations (determined by carrier gas hot extraction) enables the identification of realistic diffusion coefficients.

Highlights

  • Martensitic 9% Cr steels like P91 (X10CrMoVNb9-1) or P92 (X10CrWMoVNb9-2) are widely used for fossil or nuclear power plants due to their excellent creep and corrosion resistance [1, 2]

  • The diffusion coefficients were calculated by the time-lag method (“Dlag”, see Eq 6) and the inflection point method (“DIP”, see Eq 8)

  • The corresponding hydrogen diffusion coefficients were calculated by time-lag method [36, 37] and inflection point method [38]

Read more

Summary

Introduction

Martensitic 9% Cr steels like P91 (X10CrMoVNb9-1) or P92 (X10CrWMoVNb9-2) are widely used for fossil or nuclear power plants due to their excellent creep and corrosion resistance [1, 2]. Recommended for publication by Commission IX - Behaviour of Metals Subjected to Welding. Fusion welding is carried out for component fabrication. The ferritic-martensitic microstructure demands careful welding fabrication [2]. The welding process of martensitic Cr steels itself is followed by a multi-step heat treatment procedure:. (1) After welding, the components are cooled down to a temperature around 80 °C to limit thermally induced stresses and to ensure a fully martensitic transformation. A hydrogen removal heat treatment (HRHT) or dehydrogenation heat treatment (DHT) is carried out, followed by cooling the joint to room temperature. It is essential for avoidance of hydrogen assisted cracking (HAC)

Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.