Abstract
The results of theoretical studies of thermal modernization of cold roof floor. The designs of overlap of long-life roofs of public buildings were considered. Overlap of these buildings are made by wooden or concrete beams and made of concrete slabs with upward edges. The problems of thermal modernization of these designs are consideration of the impact of heat-conducting inclusions on the resistance to heat. The heat-conducting inclusions of constructions are beams and vertical edges of the slabs. The results of calculations of the temperature fields were used for the analysis. The research was carried for the two temperature zones which Ukraine’s territory is divided into. The analysis of thermal protection level of structures overlap was made. The magnitude of the impact of heat-conducting inclusions on resistance to heat after thermal modernization of cold roof floor was observed. The analysis showed that the thermal protection properties of structures less than standard, therefore the insulation of areas with heat-conducting inclusions is required. The options of insulation of these areas were considered. The optimal insulation options with the least amount of additional insulation over the heat conductive areas were selected.
Highlights
One of the main tasks of external walling designing is to provide a normalized level of thermal and moisture conditions
In the roof floor buildings with long-life heat-conducting inclusions related to the vertical edges of concrete slabs, wooden beams and reinforced concrete
Increasing of the thermal-resisting properties is possible by additional insulation of heat conductive areas inclusions
Summary
One of the main tasks of external walling designing is to provide a normalized level of thermal and moisture conditions. The heat-conducting inclusions of constructions are beams and vertical edges of the slabs. The magnitude of the impact of heat-conducting inclusions on resistance to heat after thermal modernization of cold roof floor was observed. The analysis showed that the thermal protection properties of structures less than standard, the insulation of areas with heat-conducting inclusions is required.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.