Abstract
The electrical failure associated with concentration of heat and thermomechanical stress inside junction boxes is one of the main failure modes of photovoltaic (PV) modules. Three types of potting junction boxes with partial 72 Si cells PV panel are modeled under a constant current steady-state condition. The temperature distribution results are verified through thermal dissipation tests. It is found that when one diode is in the on -state, the split kind of junction box shows the highest temperature distribution on the surface, which is nearly $15\;^\circ {\rm{C}}$ higher than the other two types under $25\;^\circ {\rm{C}}$ with 11 A current applied. When three diodes are working, the other two types of junction box with three diodes inside will be intensely heated. The internal temperature distribution shows that bigger size and more copper coverage can help improve the thermal dissipation. Thermomechanical stress analysis based on the steady-state conditions is then carried out. The results show stress concentration on the side wall of the type I junction box while the other two types having conspicuous impact to the backsheet.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.