Abstract

This paper offers numerical and experimental analysis of forced convection through an annulus filled with aluminium foam. Effects of flow rate and foam pore density on the performance of the heat exchanger were investigated. Specifically, 5 and 20 pore per inch (PPI) aluminium metal foams were tested at three different airflow rates; 20, 85 and 150 standard litre per minute. In parallel, the problem has been simulated numerically. Once validated against experimental data, numerical simulations were conducted to add to the level of details obtained from experiments. The thermal study was done by analysing the temperature field throughout the porous volume and determining the thermal entrance length. This parameter, the thermal entrance length, establishes a reliable design criteria for metal foam-filled heat exchangers, since it marks the length beyond which heat transfer does not significantly increase while the pressure drop keeps growing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.