Abstract
We developed a method for simultaneous measurements of conductance and thermopower of atomic and molecular junctions by using a microheater-embedded mechanically-controllable break junction. We find linear increase in the thermoelectric voltage of Au atomic junctions with the voltage added to the heater. We also detect thermopower oscillations at several conductance quanta reflecting the quantum confinement effects in the atomic wire. Under high heater voltage conditions, on the other hand, we observed a peculiar behaviour in the conductance dependent thermopower, which was ascribed to a disordered contact structure under elevated temperatures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.