Abstract

The actual temperature rise and time-rise constant of the mask membranes during x-ray irradiation was measured using metal resistors fabricated directly on the mask. The experimental results are compared with the calculated. A model of thermoelastic distortions of the printed image during x-ray beam scanning was developed. In addition to the shift of the features the model predicts blur of the edges. Experimental results for the thermal wave effects are presented, and indicate that the effects are noticeable only during operation in a vacuum environment. The effects are negligible during normal operation in a helium atmosphere.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.