Abstract

This paper presents a thermoeconomic analysis of a polygeneration system based on solar-assisted desiccant cooling. The overall plant layout supplies electricity, space heating and cooling, domestic hot water, and freshwater for a residential building. The system combines photovoltaic/thermal collectors, photovoltaic panels, and a biomass boiler coupled with reverse osmosis and desiccant air conditioning. The plant was modeled in TRNSYS and simulated for 1 year. A parametric study defined the system’s setup. A thermoeconomic optimization determined the set of parameters that minimize the simple payback period. The optimal structure showed a total energy efficiency of 0.49 for the solar collectors and 0.16 for the solar panels. The coefficient of performance of the desiccant air conditioning was 0.37. Finally, a sensitivity analysis analyzed the influence of purchase electricity and natural gas costs and the electricity sell-back price on the system. The optimum simple payback was 20.68 years; however, the increase in the energy cost can reduce it by up to 85%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.