Abstract
Molar heat capacities at constant volume (CV) were measured with an adiabatic calorimeter for pure propane. The high purity of the samples was verified by chemical analysis. Temperatures ranged from the triple point of propane near 85 K to the upper temperature limit of the calorimeter at 345 K, while pressures ranged up to 35 MPa. Measurements were conducted on liquid propane in equilibrium with its vapor and on compressed liquid samples along isochores. Heat capacity results are reported for two-phase (CV(2)), saturated liquid (Cσ), and single-phase (CV) isochores. Vapor pressure data are based on measurements of CV(2) along a two-phase isochore. Measurements were also made to determine the triple-point temperature of (85.525 ± 0.005) K and heat of fusion of (3508 ± 20) J·mol−1 for propane near its triple point. The principal sources of uncertainty in CV are the temperature-rise measurement and the change-of-volume work adjustment. The expanded uncertainty (i.e., a coverage factor k = 2 and thus a two-standard deviation estimate) for values of CV(2) is estimated to be 0.5 %; for both Cσ and CV, it is 0.7 %.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.