Abstract

The partial and integral enthalpies of mixing of liquid Bi–Sn–Zn alloys were determined at 500°C by a drop calorimetric technique using a Calvet-type microcalorimeter. The ternary interaction parameters in the Bi–Sn–Zn system were fitted using the Redlich-Kister-Muggianu model for substitutional solutions, and isoenthalpy curves of the integral molar enthalpy of mixing at 500°C were constructed. Furthermore, a DSC technique was used to determine the liquidus temperatures in three sections (3, 5, and 7 at.% Zn) as well as the invariant reaction temperature of the ternary eutectic L ⇄ (Bi) + (Sn) + (Zn). The ternary eutectic reaction was found at 135°C.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.