Abstract

In this paper, a new heat recovery system of hot air hood of paper machine is proposed, the thermodynamic model of the system is established, and the effect of different thermal parameters on the heat recovery efficiency of the system is studied. The results indicate that both the recovered energy and the proportion of exhaust air passing through the latent heat exchanger attenuate as fresh air temperature increase and fresh air moisture content decrease. The system heat recovery increasing with rising of exhaust temperature. Exhaust temperature and exhaust relative humidity have different effects on sensible and latent heat recovery. The maximum value of proportion of exhaust air passing through latent heat exchanger appears when the exhaust relative humidity is 35.8%. Overall, the fresh air temperature and the exhaust relative humidity have great influence on the heat recovery efficiency.