Abstract

The paper presents the experimental study of an air solar installation with a collecting area AC = 4.2m² and variable working fluid flow rate in the range 0.02÷0.06 kg/s. The experimental data are processed statistically through thermodynamic analysis, using energy (semi-empirical) and exergy methods. The aim of the paper is to establish the optimal air flow rate through this solar thermal system in order to ensure minimum irreversibility of the collecting-heating-cooling process under Romania's insolation conditions. The paper is also a demonstrative example of cost-effective and efficient use of solar energy for heating in Romania. It is experimentally proven that for this solar installation, the optimum air flow rate is of 0.04 kg/s. At a flow rate of 0.04 kg/s, irreversibility has the lowest values for all daytime hours with a maximum at noon (2640 W). For this flow rate the exergy efficiency reaches the highest value, ηex:max = 0:197.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.