Abstract

A modified catheter has been used in conjunction with a thermodilution cardiac output computer for postoperative assessment of cardiac function in infants and children. Because of the small amount of fluid required for each determination and the simplicity of the technique, serial measurements can be done safely. Its use has a contributed to the early detection of low output states. It has also proven to be a useful tool for estimating the optimal heart rate in each patient and for assessing the effectiveness of therapeutic measures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.